본문 바로가기
기계시스템 안전이야기

ISO 13849-1 : Standard of Industrial Safety, Performance Level d (PL d)

by 엘레펀트인덱스 2026. 1. 8.
PL d Advanced Training: Control System Safety Guide
ISO 13849-1 Advanced Course

Standard of Industrial Safety,
Performance Level d (PL d)

Why do robots and automation systems require PL d?
Learn the design know-how to reduce the probability of dangerous failure to 1 in 10 million.

Module 1. Definition and Meaning of PL d

How safe must it be to be PL d?

Probability of Dangerous Failure per Hour (PFHd)

The PL grade is not just saying "it's safe".
It quantifies the "probability of a dangerous failure occurring during 1 hour of operation".

PL PFHd (1/h) Reliability Level
PL c ≥ 10-6 ~ < 3 × 10-6 1 in a Million
PL d ≥ 10-7 ~ < 10-6 1 in 10 Million
PL e ≥ 10-8 ~ < 10-7 1 in 100 Million

Why is PL d for Robots?

  • S2
    Serious Injury (Severity) Possibility of fracture, amputation, or death upon collision.
  • F2
    Frequent Exposure (Frequency) Operators frequently approach the robot in automation lines.
  • P1
    Possibility of Avoidance Can be avoided under specific conditions (e.g., slow speed).
Risk Assessment Result ⇒ Minimum PL d Required

Module 2. Recipe to Achieve PL d

The standard design combination to achieve PL d

The Golden Formula for PL d

Most common "Category 3" based configuration

1

Category 3

Architectural Requirements

Redundancy

No loss of safety function
even with a single fault

2

MTTFd

Component Reliability

Medium ~ High

Use certified components
with low failure rates (Check B10d)

3

DCavg

Diagnostic Coverage

Low ~ Medium

Cross-check (Feedback)
of I/O status

Note: While theoretically Category 2 (Single channel + Test) can achieve PL d, Category 3 (Redundancy) is the industrial standard for robot systems due to control complexity and test cycle limitations.

Module 3. Practical Circuit Design (Category 3)

Example of perfect redundancy from input to output

INPUT
E-Stop Button
NC 1
NC 2

★ 2 Contacts (Redundancy)

LOGIC
Safety PLC / Relay
Channel A Processing Channel B Processing
Cross Monitoring
OUTPUT
Power Cut-off (MC)
MC 1
MC 2

★ Series Connection

Common Mistakes (Failure Causes)

  • Single Contact: Connecting E-Stop with only 1 contact (Cat 1 or lower).
  • Standard PLC: Handling Safety Functions with standard PLC logic (No diagnostics).
  • Fault Masking: Simple series connection of multiple E-Stop buttons prevents fault detection.

Success Points (Check Point)

  • EDM Mandatory: Feedback of the output MC's auxiliary contact (NC) to the safety controller.
  • CCF Consideration: Separate cabling or shielding to prevent common cause failures.

Module 4. Verification & Software

Manual PL calculation is prone to errors. Verification software is used in the industrial field.

P
PAScal Safety calculation software by Pilz
S
SISTEMA Free standard tool by IFA (Widely used)

Education Material

Based on EN ISO 13849-1:2015

Advanced Safety Training

© Safety Guide. Specialized for PL d.