Standard of Industrial Safety,
Performance Level d (PL d)
Why do robots and automation systems require PL d?
Learn the design know-how to reduce the probability of dangerous failure to 1 in 10 million.
Module 1. Definition and Meaning of PL d
How safe must it be to be PL d?
Probability of Dangerous Failure per Hour (PFHd)
The PL grade is not just saying "it's safe".
It quantifies the "probability of a dangerous failure occurring during 1 hour of operation".
| PL | PFHd (1/h) | Reliability Level |
|---|---|---|
| PL c | ≥ 10-6 ~ < 3 × 10-6 | 1 in a Million |
| PL d | ≥ 10-7 ~ < 10-6 | 1 in 10 Million |
| PL e | ≥ 10-8 ~ < 10-7 | 1 in 100 Million |
Why is PL d for Robots?
-
S2
Serious Injury (Severity) Possibility of fracture, amputation, or death upon collision.
-
F2
Frequent Exposure (Frequency) Operators frequently approach the robot in automation lines.
-
P1
Possibility of Avoidance Can be avoided under specific conditions (e.g., slow speed).
Module 2. Recipe to Achieve PL d
The standard design combination to achieve PL d
The Golden Formula for PL d
Most common "Category 3" based configuration
Category 3
Architectural Requirements
RedundancyNo loss of safety function
even with a single fault
MTTFd
Component Reliability
Medium ~ HighUse certified components
with low failure rates (Check B10d)
DCavg
Diagnostic Coverage
Low ~ MediumCross-check (Feedback)
of I/O status
Note: While theoretically Category 2 (Single channel + Test) can achieve PL d, Category 3 (Redundancy) is the industrial standard for robot systems due to control complexity and test cycle limitations.
Module 3. Practical Circuit Design (Category 3)
Example of perfect redundancy from input to output
★ 2 Contacts (Redundancy)
★ Series Connection
Common Mistakes (Failure Causes)
- Single Contact: Connecting E-Stop with only 1 contact (Cat 1 or lower).
- Standard PLC: Handling Safety Functions with standard PLC logic (No diagnostics).
- Fault Masking: Simple series connection of multiple E-Stop buttons prevents fault detection.
Success Points (Check Point)
- EDM Mandatory: Feedback of the output MC's auxiliary contact (NC) to the safety controller.
- CCF Consideration: Separate cabling or shielding to prevent common cause failures.
Module 4. Verification & Software
Manual PL calculation is prone to errors. Verification software is used in the industrial field.
'기계시스템 안전이야기' 카테고리의 다른 글
| 에너지 차단 및 잠금 조치LOTO (Lockout/Tagout) (0) | 2026.01.08 |
|---|---|
| 자율안전확인신고 (KCs) (0) | 2026.01.08 |
| ISO 13849-1 심화 과정 : 왜 로봇과 자동화 설비는 PL d를 요구할까요? (0) | 2026.01.08 |
| EN ISO 13849-1 : 2015 / 제어 시스템의 안전 관련 부품 (0) | 2026.01.08 |
| EN ISO 10218-1/-2 : 로봇시스템 안전 규격 (0) | 2026.01.08 |